Pitäisi saada minimikoko formille, että sen pienemmäksi sitä ei saa laitettua "draggaamalla". Löysin ohjeita googlettamalla ja tämä ajoi asiaa:
Formi ------ Option Explicit ' A demo project showing how to prevent the user from making a window smaller ' or larger than you want them to, through subclassing the WM_GETMINMAXINFO message. ' by Bryan Stafford of New Vision Software® - newvision@mvps.org ' this demo is released into the public domain "as is" without ' warranty or guaranty of any kind. In other words, use at ' your own risk. Private Sub MDIForm_Load() ' take control of message processing by installing our message handling ' routine into the chain of message routines for this window g_nProcOld = SetWindowLong(hWnd, GWL_WNDPROC, AddressOf WindowProc) End Sub Private Sub MDIForm_Unload(Cancel As Integer) ' give message processing control back to VB ' if you don't do this you WILL crash!!! Call SetWindowLong(hWnd, GWL_WNDPROC, g_nProcOld) End Sub Moduuli --------- Option Explicit ' A demo project showing how to prevent the user from making a window smaller ' or larger than you want them to, through subclassing the WM_GETMINMAXINFO message. ' by Bryan Stafford of New Vision Software® - newvision@mvps.org ' this demo is released into the public domain "as is" without ' warranty or guaranty of any kind. In other words, use at ' your own risk. ' See the comments at the end of this module for a brief explaination of ' what subclassing is. Type POINTAPI x As Long y As Long End Type ' the message we will subclass Public Const WM_GETMINMAXINFO As Long = &H24& Type MINMAXINFO ptReserved As POINTAPI ptMaxSize As POINTAPI ptMaxPosition As POINTAPI ptMinTrackSize As POINTAPI ptMaxTrackSize As POINTAPI End Type ' this var will hold a pointer to the original message handler so we MUST ' save it so that it can be restored before we exit the app. if we don't ' restore it.... CRASH!!!! Public g_nProcOld As Long ' declarations of the API functions used Public Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" (lpDest As Any, lpSource As Any, _ ByVal cBytes&) Public Declare Function CallWindowProc& Lib "user32" Alias "CallWindowProcA" (ByVal lpPrevWndFunc&, _ ByVal hWnd&, ByVal Msg&, ByVal wParam&, ByVal lParam&) Public Const GWL_WNDPROC As Long = (-4&) ' API call to alter the class data for a window Public Declare Function SetWindowLong Lib "user32" Alias "SetWindowLongA" (ByVal hWnd&, _ ByVal nIndex&, ByVal dwNewLong&) As Long 'WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! ' ' Do NOT try to step through this function in debug mode!!!! ' You WILL crash!!! Also, do NOT set any break points in this function!!! ' You WILL crash!!! Subclassing is non-trivial and should be handled with ' EXTREME care!!! ' ' There are ways to use a "Debug" dll to allow you to set breakpoints in ' subclassed code in the IDE but this was not implimented for this demo. ' 'WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! WARNING!!!! Public Function WindowProc(ByVal hWnd As Long, ByVal iMsg As Long, _ ByVal wParam As Long, ByVal lParam As Long) As Long ' this is *our* implimentation of the message handling routine ' determine which message was recieved Select Case iMsg Case WM_GETMINMAXINFO ' dimention a variable to hold the structure passed from Windows in lParam Dim udtMINMAXINFO As MINMAXINFO Dim nWidthPixels&, nHeightPixels& nWidthPixels = Screen.Width \ Screen.TwipsPerPixelX nHeightPixels = Screen.Height \ Screen.TwipsPerPixelY ' copy the struct to our UDT variable CopyMemory udtMINMAXINFO, ByVal lParam, Len(udtMINMAXINFO) With udtMINMAXINFO ' set the width of the form when it's maximized .ptMaxSize.x = nWidthPixels - (nWidthPixels \ 4) ' set the height of the form when it's maximized .ptMaxSize.y = nHeightPixels - (nHeightPixels \ 4) ' set the Left of the form when it's maximized .ptMaxPosition.x = nWidthPixels \ 8 ' set the Top of the form when it's maximized .ptMaxPosition.y = nHeightPixels \ 8 ' set the max width that the user can drag the form .ptMaxTrackSize.x = .ptMaxSize.x ' set the max height that the user can drag the form .ptMaxTrackSize.y = .ptMaxSize.y ' set the min width that the user can drag the form .ptMinTrackSize.x = nWidthPixels \ 4 ' set the min width that the user can drag the form .ptMinTrackSize.y = nHeightPixels \ 4 End With ' copy our modified struct back to the Windows struct CopyMemory ByVal lParam, udtMINMAXINFO, Len(udtMINMAXINFO) ' return zero indicating that we have acted on this message WindowProc = 0& ' exit the function without letting VB get it's grubby little hands on the message Exit Function End Select ' pass all messages on to VB and then return the value to Windows WindowProc = CallWindowProc(g_nProcOld, hWnd, iMsg, wParam, lParam) End Function ' What is subclassing anyway? ' ' Windows runs on "messages". A message is a unique value that, when ' recieved by a window or the operating system, tells either that ' something has happened and that an action of some sort needs to be ' taken. Sort of like your nervous system passing feeling messages ' to your brain and the brain passing movement messages to your body. ' ' So, each window has what is called a message handler. This is a ' function where all of the messages FROM Windows are recieved. Every ' window has one. This means every button, textbox, picturebox, form, ' etc... Windows keeps track of where the message handler (called a ' WindowProc [short for PROCedure]) in a "Class" structure associated ' with each window handle (otherwise known as hWnd). ' ' What happens when a window is subclassed is that you insert a new ' window procedure in line with the original window procedure. In other ' words, Windows sends the messages for the given window to YOUR WindowProc ' FIRST where you are responsible for handling any messages you want to ' handle. Then you pass the remaining messages on to the default ' WindoProc. So it looks like this: ' ' Windows Message Sender --> Your WindowProc --> Default WindowProc ' ' A window can be subclassed MANY times so it could look like this: ' ' Windows Message Sender --> Your WindowProc --> Another WindowProc _ ' --> Yet Another WindowProc --> Default WindowProc ' ' You can also change the order of when you respond to a message by ' where in your routine you pass the message on to the next WindowProc. ' Let's say that you want to draw something on the window AFTER the ' default WindowProc handles the WM_PAINT message. This is easily done ' by calling the default proc before you do your drawing. Like so: ' ' Public Function WindowProc(Byval hWnd, Byval etc....) ' ' Select Case iMsg ' Case SOME_MESSAGE ' DoSomeStuff ' ' Case WM_PAINT ' ' pass the message to the defproc FIRST ' Call CallWindowProc(m_g_nProcOld, hWnd, iMsg, wParam, lParam) ' ' DoDrawingStuff ' <- do your drawing ' ' WindowProc = nYourReturnVal ' <- retrun the desired value ' ' to the system ' ' Exit Function ' <- exit since we already passed the ' ' measage to the defproc ' ' End Select ' ' ' pass all messages on to VB and then return the value to windows ' WindowProc = CallWindowProc(m_g_nProcOld, hWnd, iMsg, wParam, lParam) ' ' End Function ' ' ' This is just a basic overview of subclassing but I hope it helps if ' you were fuzzy about the subject before reading this. '
Tämä kyllä toimi mutta en tarvitse MAX Sizeä, enkä keskitystä maxittaessa. Koitin niitä värkätä pois tosta mutta ei luonnistunu vaan formi oli missä millonkin. En sitten tiedä onko helpomaa keinoa määrittää minimikoko formille?
Laita Form_resize-tapahtumaan haluamasi minimirajat. Jos alittuvat, vaihda tilalle asettamasi minimit.
Form resizestä löytyy mm.
Const MINWIDTH As Long = 9705 Const MINHEIGHT As Long = 7020 If Me.Width < MINWIDTH Then Me.Width = MINWIDTH Exit Sub End If If Me.Height < MINHEIGHT Then Me.Height = MINHEIGHT Exit Sub End If Chat_Box.Height = Main.Height - 3000 Chat_Box.Width = Main.Width - 500
jne. Eli tekstikentät ja muut muuttuvat resizen yhteydessä. Kaikki toimii oikein kunnes painaa minimize nappia ja...
http://elektroniikka.org/vb_error.jpg koitin korjata ongelmaa laittamalla form resizeen iffiä että jos ikkuna on normal niin nuita suoritetaan mutta mutoin ei. Samaa erkkiä herjaa.
eikö toimi jos laitat seuraavasti?
Const MINWIDTH As Long = 9705 Const MINHEIGHT As Long = 7020 If Form1.WindowState = 0 Then If Me.Width < MINWIDTH Then Me.Width = MINWIDTH Exit Sub End If If Me.Height < MINHEIGHT Then Me.Height = MINHEIGHT Exit Sub End If Chat_Box.Height = Me.Height - 3000 Chat_Box.Width = Me.Width - 500 End If
Nyt se ei herjää kun iskee minimizediä, mutta sitten kun painetaan maximize niin sehän ei muuta laatikoiden kokoja koska If Main.WindowState = 0 Then koskee vaan normaalia ikkunaa. Jos lisään tuohon että jos main on normal TAI main on maximized ( If Main.WindowState = 0 Or 1 Then ) niin koot muutetaan, muutoin ei. No teinpä niin ja laatikot muuttuu kivasti mutta sitten kun minimisoi kummassa tahansa tilassa niin samaa erkkiä pukkaa.
sen maximized tilan numerokoodi on 2
Testasin myös kakkosella mutta sama homma :\
Laita alkuun ehtolause:
If Me.WindowState <> 0 Then Exit Sub
Tai näin, niin toimii maxButtonillakin:
If Me.WindowState = 1 Then Exit Sub